Electron microscope service, Australia
JEOL electron microscope repair for Australian laboratories
Ketna is an independent service team in Warsaw that diagnoses and repairs JEOL SEM and TEM instruments. Send us the error messages, a few photos and a short description of the fault, and we will reply with a technical assessment and a plan.
Who we are
An independent option when your microscope stops working
When an SEM or TEM goes down, a research group or production line loses its imaging. Many Australian instruments sit outside a manufacturer contract because the warranty has ended, the model is older or the budget no longer stretches. That gap is where Ketna works.
We are a small company in Warsaw, Poland. Our engineers gained their experience in the JEOL Polska service environment and now work independently, not as the manufacturer or an authorised partner. You deal directly with the person doing the repair.

Services
What we do for SEM and TEM users
Each job in Australia starts from a short technical intake. Then we agree the scope in writing: what will be checked, what may need replacing and what is left out.
Fault diagnosis and repair
Vacuum faults, high-voltage errors, unstable emission, stage, detector and console to PC communication problems. We find the cause before recommending parts.
Preventive maintenance
Scheduled checks of vacuum, pumps, apertures, cooling water and electronics, so wear is picked up early and image quality stays consistent.
Filament and electron source work
Tungsten and LaB6 filament replacement, gun alignment and conditioning. On field emission instruments we assess the emitter and gun vacuum first.
Spare parts
Original parts where they can still be sourced, technically justified alternatives where they cannot, with a clear reason for each.
Relocation and reinstallation
Moving an instrument to a new room or campus: shutdown, packing guidance, reassembly, pump-down and checks.
Operator training
Hands-on sessions on daily operation, alignment and first-line checks, so small issues never turn into downtime.
Supported instruments
JEOL model families we work on
Support depends on the model, the fault and parts availability. If yours is not listed, send the model name and we will tell you plainly whether we can help.
JSM-6000 series SEM
Tungsten and LaB6 instruments such as the JSM-6390, 6490, 6510 and 6610, still common in teaching labs and QC rooms.
JSM-7000F field emission SEM
FEG-SEM models including the JSM-7001F, 7100F, 7600F and 7800F, used for high-resolution imaging and microanalysis.
JSM-IT series and JCM benchtop
The JSM-IT100, IT200, IT300 and IT500, plus JCM benchtop SEMs used in smaller labs and on production sites.
TEM and FIB-SEM
JEM-1011 and JEM-1400 TEMs, the JEM-2100 and 2100F, and JIB series FIB-SEM systems.
Common faults
Signs your microscope needs attention
Vacuum will not reach ready state
Long pump-down, interlock messages or vacuum lost mid-session, often from a seal, valve, gauge or worn pump.
Unstable or missing beam
Drifting emission current, filaments burning out early, or no image once the high voltage is on.
Image quality has dropped
Astigmatism that will not correct, drift, new charging artefacts, or noise at every setting.
Stage or specimen holder problems
Uneven movement, lost position, stops at the limits, or a failed specimen exchange.
Detector faults
Weak or missing SE or BSE signal, or an EDS detector the software no longer recognises.
Software and communication errors
The PC cannot reach the microscope, error codes appear at start-up, or the software hangs after an update.
Working from Australia
How service works across the time zones
Most cases start remotely. A photo of an error screen, a log file or a sample image often says more than a long call, and lets us prepare before anyone travels or orders parts.
Time difference
Australia is ahead of Poland by 8 to 10 hours on the east coast, 7.5 to 9.5 in Adelaide and 6 to 7 in Perth, depending on daylight saving in both countries. Calls are booked for your afternoon, the start of the Warsaw working day.
Remote diagnosis in English
Send photos, error messages, logs and sample images. We review them and suggest checks your staff can run. Some faults end there; others need parts or a visit, agreed case by case. All in English, by email or video call.
Parts, freight and customs
Parts ship from the European Union. Import duty, GST and clearance charges follow Australian rules and are set out in the quote before you commit.

How it works
From first email to a working instrument
The steps stay the same for minor and serious faults. Only the share of remote work changes.
Technical intake
You describe the problem and send the model, serial number, error messages and photos.
Remote assessment
We go through the material, may ask for extra tests, and tell you what we think is behind the fault.
Plan and quote
A written proposal covering remote support, parts, a visit or a mix. Costs, freight, duties and timing are stated before work starts.
Repair and handover
The instrument is repaired and tested, with a short report on findings, replaced parts and what to watch.
Across Australia
Labs and industries we can support in Australia
Australian electron microscopes sit in university microscopy centres, research agencies, hospitals and industrial sites. In Western Australia and Queensland, SEM-based automated mineralogy supports ore characterisation. Steel and materials research has deep roots in Wollongong and Newcastle, and Melbourne, Sydney and Brisbane carry much of the biomedical work.
Canberra hosts national research institutions, Hobart focuses on marine and Antarctic science, Townsville on tropical and reef research. Distances are long, so we diagnose remotely first and plan a visit only once the fault is understood.
Before you contact us
What to prepare
Ten minutes of preparation saves days of emails across a big time difference.
Instrument details
Model, approximate installation year, serial number, and attachments such as EDS, EBSD or cryo equipment.
The fault in your own words
When it started, what changed beforehand, whether it is constant or intermittent, and what you have tried.
Evidence
Photos of error screens, exported logs, a sample image showing the problem, and a photo of the vacuum display.
FAQ
Questions about JEOL service in Australia
Is Ketna part of JEOL?
No. Ketna is independent, not an authorised partner, and does not act for the manufacturer. JEOL is a trademark of JEOL Ltd.
Can you help a lab in Australia?
Yes. Diagnosis starts remotely by email and video call, parts ship from the EU, and an on-site visit is agreed once the fault is clear.
How does remote diagnosis work?
Photos, error messages, log files and a few sample images come to us first. We analyse them, may ask for simple checks, then propose a remote fix, parts or a visit.
Which JEOL models do you support?
The JSM-6000, JSM-7000F and JSM-IT SEM families, JCM benchtops, JEM-1011, JEM-1400, JEM-2100 and 2100F TEMs, and JIB FIB-SEM, depending on model, fault and parts availability.
We have a manufacturer contract. Do we need you?
If your instrument is under a manufacturer contract, use it first. Ketna suits instruments outside a contract, older models, or labs wanting an independent opinion.
What should we send with the first enquiry?
Model and serial number, the fault description, photos of error messages, exported logs and a sample image showing the problem.
Contact
Tell us what is wrong with your microscope
Email works best from Australia because it gets around the time difference. Write in English, attach what you have, and we will reply with questions or a first assessment.
What happens next
We read your message and the material, then ask for more detail or propose the next step. Nothing starts until you accept a written quote.