Serwis Mikroskopów Ketna

Repair and servicing of JEOL electron microscopes in Singapore

Serwis Mikroskopów Ketna > Repair and servicing of JEOL electron microscopes in Singapore

Independent JEOL service for Singapore

Repair and servicing of JEOL electron microscopes in Singapore

Ketna is a small, independent team in Warsaw that troubleshoots and repairs JEOL SEM and TEM instruments. Share the error screens, log files and a recent image with us, and we will come back with a likely cause and a proposed next step. We work in English from start to finish.

SEM / TEMFault-finding, repairs and planned maintenance
SGRemote review first, site visits by arrangement
JEOLModel families across several generations
EUParts dispatched from Europe

About Ketna

An independent team focused on JEOL instruments

We are based in Warsaw, Poland. The team built its technical background in the JEOL Polska service environment and today operates on its own, without any link to the manufacturer.

Singapore teams tend to contact us about an instrument that has come off its service agreement, or when they want an independent view of a fault before raising a purchase order. We start from the evidence your microscope already gives you.

Service engineer inspecting the electron column of a JEOL SEM

What we do

Services for SEM and TEM owners

We scope each job after a technical intake. What we can take on depends on the model, the fault and whether parts can be sourced.

01

Troubleshooting and repair

Vacuum and pumping faults, high-voltage trips, stage and goniometer errors, detector failures and unstable imaging. Cause first, parts second.

02

Planned maintenance

Scheduled inspection of the vacuum system, chiller and water circuit, gun chamber and stage mechanics, to catch slow deterioration early.

03

Filaments and emitters

Replacing tungsten and LaB6 filaments, aligning the gun, and checking emitter conditions on field emission columns.

04

Spare parts sourcing

Genuine parts where they are still available and technically sound alternatives where they are not. The reasoning comes in writing.

05

Moves and re-installation

Shutting an instrument down for a lab move, advising on packing, and recommissioning it afterwards.

06

User training

Hands-on sessions for new operators and facility staff on routine operation and basic care.

Instruments

Which JEOL microscopes we cover

Coverage depends on model, fault and parts availability. Please quote the exact model and software version.

JSM-6000 series

Conventional SEMs such as the JSM-6390, 6490, 6510 and 6610, common in teaching labs and incoming inspection.

JSM-7000F field emission SEMs

The 7001F, 7100F, 7600F and 7800F, typically used for high-magnification imaging and microanalysis.

JSM-IT and JCM benchtop

IT100, IT200, IT300 and IT500 models, and compact JCM benchtop units placed close to production or in smaller labs.

JEM TEMs and JIB FIB-SEM

JEM-1011, JEM-1400, JEM-2100 and 2100F transmission microscopes, plus JIB dual-beam systems

Typical faults

When to get in touch

Pump-down takes too long

The chamber never reaches operating vacuum, interlocks stay active, or pressure creeps up during a session.

Unstable or missing beam

Emission current wanders, filaments fail early, or the gun trips before reaching the set voltage.

Image quality has slipped

Drift, periodic noise or a loss of resolution at magnifications that used to be routine.

Stage behaving oddly

Axes that stop halfway, poor repeatability, or limit errors after a power interruption.

Detector or EDS problems

A dim SE image, a weak BSE signal, or EDS spectra with unexpected peaks or unusually low counts.

Unfamiliar error messages

Codes that appear after a PC or software update, a facility shutdown or months on standby.

Working from Europe

How we support Singapore labs from Poland

Most diagnostic work happens by email and video call.

Time difference

Singapore is seven hours ahead of Poland during the European winter and six hours ahead while Poland is on summer time, as Singapore does not change its clocks. Calls are usually set for your afternoon, our morning.

Diagnosis before dispatch

Screenshots, exported logs and sample images let us narrow down the likely cause. We then recommend remote guidance, a parts shipment or an on-site visit, agreed for each case.

Parts, GST and language

Parts are shipped from the EU. Import GST and any other charges follow Singapore rules and are set out in the quotation. All technical communication is in English.

JEOL SEM TEM Ketna

How it works

From first email to completed repair

There is no portal or account. You describe the fault, we reply with questions and a proposal.

Intake

Send the model, year of installation, a description of what the instrument is doing and any files that show it.

Remote review

We go through the material and, where it helps, arrange a video call while the microscope is running.

Quotation

A written proposal covers remote support, parts, freight and, if required, a site visit.

Repair and verification

We carry out the agreed work, then confirm the result with you using test images of your own specimens.

Singapore

Where electron microscopy is used in Singapore

SEM and TEM work in Singapore centres on semiconductor manufacturing and failure analysis, advanced materials and biomedical research. In shared facilities a few instruments often serve many groups, so downtime is felt widely.

Research activity clusters around one-north, home to Biopolis and Fusionopolis, and around Kent Ridge and the Nanyang campus in the west. Wafer fabs operate in Woodlands, Tampines, Pasir Ris and Ang Mo Kio, while Jurong hosts industrial and chemical companies.

one-north (Biopolis, Fusionopolis)Kent RidgeNanyang / Jurong WestJurongJurong IslandWoodlandsTampinesPasir RisAng Mo KioScience ParkSeletar

Preparation

Information to have ready

A detailed first message usually saves one or two rounds of questions.

About the instrument

Model, approximate installation year, fitted detectors and the software version displayed on start-up.

About the fault

Photos of error screens, exported logs, when the problem first appeared and anything that changed around that time.

Reference images

One image from when the instrument was performing well and one showing the problem, ideally of a similar specimen at matching settings.

FAQ

Common questions from Singapore labs

Is Ketna affiliated with JEOL?

No. Ketna is an independent Polish company. JEOL is a trademark of JEOL Ltd., and we have no connection with that company. Our engineers’ background is in the JEOL Polska service environment.

Can you support a lab or fab in Singapore?

Yes. We begin with remote diagnosis from Poland, send parts from the EU when they are needed, and arrange any on-site work case by case.

What does remote diagnosis involve?

You share photos, error messages, logs and sample images. We study them, ask follow-up questions and may suggest a video call with the instrument switched on. This often rules out several causes before parts are ordered.

Which JEOL models can you work on?

JSM-6000 and JSM-7000F series SEMs, JSM-IT and JCM benchtop instruments, JEM-1011, JEM-1400 and JEM-2100/2100F TEMs, and JIB FIB-SEM systems, subject to the model, the fault and parts availability.

Our instrument is still under a manufacturer service contract. Should we contact you?

Use the contract first if it covers the problem. Labs usually come to us once a system is out of contract, for older instruments, or for an independent second opinion. If the manufacturer is the better route, we will tell you.

What should our first email contain?

The model, installation year, a short description of the fault, photos of error messages, logs and two or three sample images. Send it to service.ketna@gmail.com.

Get in touch

Describe the problem with your JEOL microscope

Email works best across a six or seven hour time difference. If you prefer a call, suggest a few afternoon slots in Singapore time.

After you write

We reply with follow-up questions or an initial assessment and suggest what to do next. Nothing is ordered or booked until you confirm in writing.

pl_PLPolski